003ECA
p2: 3 to -3 @61, 5 to -5 @101, 10 to -10 @ 101
p3: 10 to -10 @101, 10 to -10 @101 (Keithley error at like -6 V, managed to save the scan)
p4: 5 to -5 @101, 5 to -5 @101
p5: 3 to -3 @61, 3 to -3 @61 (just noise, but a tiny response in the beginning?)
p6: 3 to -3 @61, 3 to -3 @61
p7: 5 to -5 @101, 5 to -5 @101 (keithley error, not saved)
p8: 10 to -10 @101, 10 to -10 @101

- pixel 2 looked burnt afterwards
- changed photodiode position for each pixel

003ECB
p2: 3 to -3 @61, 5 to -5 @101, 10 to -10 @ 101 (seems to have died after the one to 5, just noise on 10)
p3: 10 to -10 @ 101 (just noise), 5 to -5 @101 (just noise)
p4: 5 to -5 @101 (just noise), 5 to -5 @101 (just noise)
p5: 3 to -3 @61 (just noise), 3 to -3 @61 (just noise)
p6: 3 to -3 @61 (just noise)
p7: 5 to -5 @10 (just noise)
p8: 10 to -10 @51 (just noise)

- did not change photodiode positions, kept in position 2

003ECC
p2: 3 to -3 @61 (did well until 2.5 V then just noise, then seemed to react again at -3), 5 to -5 @101(did well from 5 to 1, then just noise, response again below -3.5), 10 to -10 @51 (died around 5?)
p3: 10 to -10 @101, 10 to -10 @101 (for some reason all the scans on p3 and the 10 V scan on p2 look exactly the same?)
p4: 5 to -5 @101, 5 to -5 @101
p5: 3 to -3 @61, 3 to -3 @61
p6: 3 to -3 @61,3 to -3 @61
p7: 5 to -5 @101, 5 to -5 @101
p8: 10 to -10 @101, 10 to -10 @101

- did not change photodiode positions, kept in position 2

003ECD
p2: 3 to -3 @61, 5 to -5 @101, 10 to -10 @101 (keithley error, not saved)
p3: 10 to -10 @101
p4: 5 to -5 @101
p5: 3 to -3 @61
p6: 3 to -3 @61
p7: 5 to -5 @101 (keithley error, not saved)
p8: 10 to -10 @101


- did not change photodiode positions, kept in position 2

003ECB retry
p3: 10 to -10 @101 (keithley error, not saved)
p4: 5 to -5 @101
p5: 3 to -3 @61
p6: 3 to -3 @61
p7: 5 to -5 @101
p8: 10 to -10 @101
- did not change photodiode positions, kept in position 2